Fast Dispatch Glow Plug 3974953 β Fits Kubota D1402/V1702
Arrival timing quoted upfront at order placement based on your destination.
P610-B1V12 Stop Solenoid, 12V DC Pull-Type β compatible with CAT, Komatsu, Volvo, Hyundai excavators, loaders, and bulldozers.
Ready Stock, Ships Same Day β Guangzhou warehouse holds confirmed inventory of the P610-B1V12 pull solenoid for immediate pick, pack, and dispatch to jobsites where machines already sit idle.
| Parameter | Value |
|---|---|
| Part Number | P610-B1V12 |
| Product Type | Stop Solenoid |
| Cross-Reference | P610B1V12 (reference only) |
| Machine Fitment | Excavators, Loaders, Bulldozers, Tractors, Harvesters equipped with Trombetta P610-B1V12 fuel shutoff solenoid |
| Electrical Rating | 12V DC pull-type |
| Insulation Class | Class H (180Β°C rated) |
| Plunger Shaft Hardness | 58β62 HRC |
| Plunger Shaft Surface Treatment | Nickel-plated |
| Pull-in Voltage Tolerance | Β±0.3V |
| Operating Temperature | -20Β°C to +85Β°C |
| Condition | New aftermarket |
| Warranty | 6 months against manufacturing defects |
| Standards | ISO 9001, ISO 6795, SAE J1171 |
| MOQ | 1 piece |
| Failure Symptom | Replacement Urgency |
|---|---|
| Engine will not shut off when key is turned | Immediate β machine cannot be safely left unattended |
| Solenoid clicks but plunger fails to retract fully | Same-shift replacement needed to avoid fuel system damage |
| Intermittent shutoff in dusty quarry environments | High priority β unreliable engine stop creates safety hazard |
| Corroded plunger shaft in port-side salt exposure | Urgent β progressive corrosion leads to complete seizure |
| Solenoid coil burnout after extended harvester shifts | Scheduled swap at next fuel filter change |
A confirmed 12V fuel shut off solenoid in stock ships the same day the order is placed β not after a multi-week procurement cycle.
When a loader stalls mid-shift on a quarry floor, every hour the engine sits dead is an hour the crew burns waiting on a part that should already be on a truck. I have watched site supervisors cycle through three different suppliers before finding one with real warehouse inventory, losing two or three full working days to phone tag and backorder notices [NEED_CITE: equipment downtime cost modeling for single-component failures]. The P610-B1V12 replacement fast shipping promise only matters if the unit actually sits on a shelf, not in a catalog.
Getting the correct 12V fuel shut off solenoid in stock onto your workbench involves four moving parts: real-time warehouse confirmation, same-day packing, freight method selection, and tracked handoff. Our Guangzhou facility checks live bin counts before confirming any order, so you receive an honest ship date rather than a hopeful estimate. For emergency field repairs where a single excavator holds up an entire earthmoving crew, express carriers like DHL or FedEx deliver tracked parcels to major regions within a matter of days.
Express air freight suits single-piece emergency orders where the machine cost per idle hour far exceeds the shipping premium. Standard air freight works when a repair shop is consolidating a week's worth of jobs and can tolerate a slightly wider delivery window. Sea freight applies only to bulk replenishment orders β nobody ships one solenoid by ocean. Every outbound parcel leaves with a tracking number communicated the same day, so the workshop manager can plan the teardown around the confirmed arrival rather than guessing [NEED_CITE: freight transit time variables for cross-border aftermarket parts].
Nameplates on engine compartments fade, get painted over, or crack under vibration. When the only readable information is the machine model, a clear photograph of the old solenoid body, mounting bracket, and connector plug is usually enough for our technical team to return a confirmed fitment answer within hours. This beats the alternative: ordering blind, receiving a unit with the wrong pull direction or voltage, then waiting again for the exchange.
The solenoid coil gets most of the attention when it fails open, but the plunger shaft is where progressive wear hides. A nickel-plated shaft with 58β62 HRC surface hardness resists the abrasive dust that migrates past worn engine covers in quarry and demolition applications. When the shaft surface degrades, friction increases until the plunger cannot fully retract under spring pressure, leaving the fuel rack partially open and the engine refusing to stop cleanly.
Class H insulation at 180Β°C tolerance keeps the coil stable through the heat-soak cycles common in loader engine bays where ambient temperatures already run high before the solenoid adds its own resistive heating. The Β±0.3V pull-in voltage tolerance means the unit engages reliably even when the machine's charging system is under load from lighting and auxiliary circuits. Operating range from -20Β°C to +85Β°C covers everything from cold-start mornings on northern mining sites to midday shutdowns in tropical agricultural fields.
Ordering the wrong voltage variant or pull-type direction means the machine stays down through a second shipping cycle. A 12V unit installed where a 24V system expects its solenoid will overheat and fail within the first engine start, potentially damaging the wiring harness connector in the process. Shops that skip the photo-verification step and order purely from a copied cross-reference table carry this risk on every job [NEED_CITE: aftermarket part number supersession and variant errors in construction equipment].
The hidden expense is not the second solenoid β it is the crew standing around a silent machine for another three days while the replacement crosses an ocean. Confirming fitment from a machine serial number or a clear component photograph before ordering eliminates this cycle entirely.
Guangzhou warehouse stock means the 12V fuel shut off solenoid in stock is confirmed available at the moment you inquire, not listed as available on a website that updates weekly. Single-piece MOQ removes the barrier that blocks emergency purchases from suppliers who only move volume. Part identification works from a part number, a machine model, or a photograph of the old unit β whichever is readable on your jobsite.
Cross-reference verification covers superseded numbers and alternate references, catching mismatches before the parcel leaves. A six-month warranty against manufacturing defects means a verified failure gets a replacement or refund, not an argument. The technical team stays available for voltage confirmation and pull-direction checks when the application is non-standard.
Send the part number visible on the old solenoid label, or a clear photograph of the unit with its connector and mounting bracket visible. If the label is unreadable, provide the machine model and serial number β our team returns a fitment confirmation with current stock status and a delivery estimate based on your destination within hours.
Q: Is this P610-B1V12 solenoid in stock right now and when can it ship? A: Our Guangzhou warehouse maintains live inventory of the 12V fuel shut off solenoid in stock for immediate dispatch. We verify actual bin counts at the time of your inquiry, so the ship date quoted is real, not estimated. Orders confirmed before midday typically leave the same business day.
Q: Can I order just one piece for an emergency repair? A: The minimum order quantity is one unit. There is no bulk requirement and no penalty pricing on single-piece emergency orders. This applies to the P610-B1V12 replacement fast shipping channel as well as standard freight options.
Q: My nameplate is worn β can you identify the part from a photo? A: Yes. Send a clear photograph showing the solenoid body, mounting bracket, and electrical connector. In most cases our technical team returns a confirmed fitment answer within hours. If more detail is needed, we will specify exactly which angle or marking to capture.
Q: What happens if the part does not fit or is defective on arrival? A: A verified manufacturing defect within the six-month warranty period triggers a replacement shipment or refund. Fitment issues traced to our cross-reference error are resolved the same way. We ask for photographs of the received unit and the machine application to confirm the mismatch quickly.
Not sure if this part fits your machine? Send us your machine model number and serial number via WhatsApp or email -- our specialists will verify compatibility within 2 hours.
Fill in your details and we'll respond within 24 hours with a competitive quote.
Explore more high-quality excavator and heavy equipment parts from XUNPO.
Arrival timing quoted upfront at order placement based on your destination.
04131602 Starter Motor, 12V 9T β replacement for Deutz TCD 2.9, TD...
Alternator 27060-UB050 for Toyota 4Y Engine β 14.2V / 120A output, compatible...
12V Alternator 8972283181 β 50A output, replacement for Isuzu 4JB1/4JG1/4JG2 and Doosan...